| End-Quench Hardenability Bands — 4042 H to 4142 H - METRIC | ||||||||||||||||
| Tabulations of Band Limits | ||||||||||||||||
“J” Distance Millimeters |
GRADE | |||||||||||||||
| 4042 H | 4047 H | 4118 H | 4130 H* | 4135 H* | 4137 H | 4140 H | 4142 H | |||||||||
| Max | Min | Max | Min | Max | Min | Max | Min | Max | Min | Max | Min | Max | Min | Max | Min | |
| 1.5 | 62 | 55 | 64 | 57 | 48 | 41 | 56 | 49 | 58 | 51 | 59 | 52 | 60 | 53 | 62 | 55 |
| 3 | 61 | 53 | 63 | 55 | 46 | 37 | 55 | 46 | 58 | 50 | 59 | 51 | 60 | 52 | 62 | 54 |
| 5 | 58 | 47 | 60 | 49 | 40 | 27 | 53 | 40 | 57 | 49 | 58 | 50 | 60 | 52 | 62 | 54 |
| 7 | 54 | 36 | 57 | 39 | 34 | 22 | 51 | 36 | 56 | 48 | 58 | 49 | 59 | 51 | 62 | 53 |
| 9 | 48 | 30 | 53 | 33 | 29 | — | 48 | 32 | 56 | 46 | 57 | 48 | 59 | 50 | 61 | 52 |
| 11 | 40 | 27 | 48 | 30 | 27 | — | 44 | 28 | 55 | 42 | 56 | 45 | 58 | 48 | 61 | 51 |
| 13 | 36 | 25 | 43 | 28 | 25 | — | 41 | 26 | 53 | 39 | 55 | 42 | 57 | 46 | 60 | 49 |
| 15 | 33 | 24 | 39 | 27 | 24 | — | 39 | 25 | 52 | 37 | 55 | 39 | 57 | 43 | 60 | 48 |
| 20 | 31 | 23 | 34 | 25 | 21 | — | 34 | 24 | 49 | 32 | 52 | 35 | 55 | 38 | 58 | 43 |
| 25 | 29 | 22 | 33 | 24 | — | — | 33 | 23 | 45 | 30 | 48 | 33 | 53 | 35 | 56 | 39 |
| 30 | 28 | 21 | 31 | 24 | 33 | 22 | 43 | 28 | 46 | 31 | 51 | 33 | 55 | 36 | ||
| 35 | 28 | 20 | 30 | 23 | 32 | 20 | 41 | 27 | 44 | 30 | 49 | 32 | 53 | 35 | ||
| 40 | 27 | — | 30 | 23 | 31 | — | 40 | 27 | 43 | 29 | 48 | 32 | 52 | 34 | ||
| 45 | 27 | — | 29 | 22 | 31 | — | 39 | 26 | 42 | 29 | 46 | 31 | 51 | 33 | ||
| 50 | 26 | — | 29 | 21 | 30 | — | 37 | 26 | 41 | 29 | 45 | 30 | 50 | 33 | ||
| NOTE: | These values were adjusted to the nearest Rockwell “C” point, and are used when points are selected and specified. |